Tag Archives: visual
Pressure Sensitive Tape Test for Quantity
Posted on 16. Mar, 2009 by charles frenzel.
Pressure Sensitive Tape Test- for Quantity The Pressure Sensitive Tape Test described by Hempel is a modification of ISO 8502-3 (Pressure Sensitive Tape test for dust) and is not mentioned in VIS-4. The tape test can be used as a permanent record. If lint deposition is a concern, the project specification may require use of [...]
Continue Reading
VIS Guides for Visual Cleanliness
Posted on 15. Mar, 2009 by charles frenzel.
Use of VIS Guides for Visual Cleanliness Immediately after the cleaning, before the surface has flash rusted, (it might still be wet), evaluate the degree of Visual Cleaning. The visual cleaning evaluation often occurs while the surface is still wet. A section was cleaned with hand-held lances over a period of 3 days. Then [...]